# Copyright 2018 The Chromium OS Authors. All rights reserved.
|
|
# Use of this source code is governed by a BSD-style license that can be
|
|
# found in the LICENSE file.
|
|
|
|
import logging
|
|
import time
|
|
|
|
from autotest_lib.client.common_lib import error
|
|
from autotest_lib.server.cros.faft.cr50_test import Cr50Test
|
|
from autotest_lib.server.cros.servo import servo
|
|
|
|
|
|
class firmware_Cr50OpenWhileAPOff(Cr50Test):
|
|
"""Verify the console can be opened while the AP is off.
|
|
|
|
Make sure it runs ok when cr50 saw the AP turn off and when it resets while
|
|
the AP is off.
|
|
|
|
This test would work the same with any cr50 ccd command that uses vendor
|
|
commands. 'ccd open' is just one.
|
|
"""
|
|
version = 1
|
|
|
|
SLEEP_DELAY = 20
|
|
SHORT_DELAY = 2
|
|
CCD_PASSWORD_RATE_LIMIT = 3
|
|
|
|
def initialize(self, host, cmdline_args, full_args):
|
|
"""Initialize the test"""
|
|
self.changed_dut_state = False
|
|
super(firmware_Cr50OpenWhileAPOff, self).initialize(host, cmdline_args,
|
|
full_args)
|
|
|
|
if not hasattr(self, 'cr50'):
|
|
raise error.TestNAError('Test can only be run on devices with '
|
|
'access to the Cr50 console')
|
|
|
|
# TODO(mruthven): replace with dependency on servo v4 with servo micro
|
|
# and type c cable.
|
|
if (self.servo.get_servo_version(active=True) !=
|
|
'servo_v4_with_servo_micro'):
|
|
raise error.TestNAError('Run using servo v4 with servo micro')
|
|
|
|
if not self.cr50.servo_dts_mode_is_valid():
|
|
raise error.TestNAError('Plug in servo v4 type c cable into ccd '
|
|
'port')
|
|
|
|
self.fast_ccd_open(enable_testlab=True)
|
|
# make sure password is cleared.
|
|
self.cr50.send_command('ccd reset')
|
|
# Set GscFullConsole to Always, so we can always use gpioset.
|
|
self.cr50.set_cap('GscFullConsole', 'Always')
|
|
# You can only open cr50 from the console if a password is set. Set
|
|
# a password, so we can use it to open cr50 while the AP is off.
|
|
self.set_ccd_password(self.CCD_PASSWORD)
|
|
|
|
# Asserting warm_reset will hold the AP in reset if the system uses
|
|
# SYS_RST instead of PLT_RST. If the system uses PLT_RST, we have to
|
|
# hold the EC in reset to guarantee the device won't turn on during
|
|
# open.
|
|
# warm_reset doesn't interfere with rdd, so it's best to use that when
|
|
# possible.
|
|
self.reset_ec = self.cr50.uses_board_property('BOARD_USE_PLT_RESET')
|
|
self.changed_dut_state = True
|
|
if self.reset_ec and not self.reset_device_get_deep_sleep_count(True):
|
|
# Some devices can't tell the AP is off when the EC is off. Try
|
|
# deep sleep with just the AP off.
|
|
self.reset_ec = False
|
|
# If deep sleep doesn't work at all, we can't run the test.
|
|
if not self.reset_device_get_deep_sleep_count(True):
|
|
raise error.TestNAError('Skipping test on device without deep '
|
|
'sleep support')
|
|
# We can't hold the ec in reset and enter deep sleep. Set the
|
|
# capability so physical presence isn't required for open.
|
|
logging.info("deep sleep doesn't work with EC in reset. skipping "
|
|
"physical presence checks.")
|
|
# set OpenNoLongPP so open won't require pressing the power button.
|
|
self.cr50.set_cap('OpenNoLongPP', 'Always')
|
|
else:
|
|
logging.info('Physical presence can be used during open')
|
|
|
|
|
|
def cleanup(self):
|
|
"""Make sure the device is on at the end of the test"""
|
|
# If we got far enough to start changing the DUT power state, attempt to
|
|
# turn the DUT back on and reenable the cr50 console.
|
|
try:
|
|
if self.changed_dut_state:
|
|
self.restore_dut()
|
|
finally:
|
|
super(firmware_Cr50OpenWhileAPOff, self).cleanup()
|
|
|
|
|
|
def restore_dut(self):
|
|
"""Turn on the device and reset cr50
|
|
|
|
Do a deep sleep reset to fix the cr50 console. Then turn the device on.
|
|
|
|
Raises:
|
|
TestFail if the cr50 console doesn't work
|
|
"""
|
|
logging.info('attempt cr50 console recovery')
|
|
|
|
# The console may be hung. Run through reset manually, so we dont need
|
|
# the console.
|
|
self.turn_device('off')
|
|
# Toggle dts mode to enter and exit deep sleep
|
|
self.toggle_dts_mode()
|
|
# Turn the device back on
|
|
self.turn_device('on')
|
|
|
|
# Verify the cr50 console responds to commands.
|
|
try:
|
|
logging.info(self.cr50.get_ccdstate())
|
|
except servo.ResponsiveConsoleError as e:
|
|
logging.info('Console is responsive. Unable to match output: %s',
|
|
str(e))
|
|
except servo.UnresponsiveConsoleError as e:
|
|
raise error.TestFail('Could not restore Cr50 console')
|
|
logging.info('Cr50 console ok.')
|
|
|
|
|
|
def turn_device(self, state):
|
|
"""Turn the device off or on.
|
|
|
|
If we are testing ccd open fully, it will also assert device reset so
|
|
power button presses wont turn on the AP
|
|
"""
|
|
# Assert or deassert the device reset signal. The reset signal state
|
|
# should be the inverse of the device state.
|
|
reset_signal_state = 'on' if state == 'off' else 'off'
|
|
if self.reset_ec:
|
|
self.servo.set('cold_reset', reset_signal_state)
|
|
else:
|
|
self.servo.set('warm_reset', reset_signal_state)
|
|
|
|
time.sleep(self.SHORT_DELAY)
|
|
|
|
# Press the power button to turn on the AP, if it doesn't automatically
|
|
# turn on after deasserting the reset signal. ap_is_on will print the
|
|
# ccdstate which is useful for debugging. Do that first, so it always
|
|
# happens.
|
|
if not self.cr50.ap_is_on() and state == 'on':
|
|
self.servo.power_short_press()
|
|
time.sleep(self.SHORT_DELAY)
|
|
|
|
|
|
def reset_device_get_deep_sleep_count(self, deep_sleep):
|
|
"""Reset the device. Use dts mode to enable deep sleep if requested.
|
|
|
|
Args:
|
|
deep_sleep: True if Cr50 should enter deep sleep
|
|
|
|
Returns:
|
|
The number of times Cr50 entered deep sleep during reset
|
|
"""
|
|
self.turn_device('off')
|
|
# Do a deep sleep reset to restore the cr50 console.
|
|
ds_count = self.deep_sleep_reset_get_count() if deep_sleep else 0
|
|
self.turn_device('on')
|
|
return ds_count
|
|
|
|
|
|
def set_dts(self, state):
|
|
"""Set servo v4 dts mode"""
|
|
self.servo.set_dts_mode(state)
|
|
# Some boards can't detect DTS mode when the EC is off. After 0.X.18,
|
|
# we can set CCD_MODE_L manually using gpioset. If detection is working,
|
|
# this won't do anything. If it isn't working, it'll force cr50 to
|
|
# disconnect ccd.
|
|
if state == 'off':
|
|
time.sleep(self.SHORT_DELAY)
|
|
self.cr50.send_command('gpioset CCD_MODE_L 1')
|
|
|
|
|
|
def toggle_dts_mode(self):
|
|
"""Toggle DTS mode to enable and disable deep sleep"""
|
|
# We cant use cr50 ccd_disable/enable, because those uses the cr50
|
|
# console. Call servo_v4_dts_mode directly.
|
|
self.set_dts('off')
|
|
|
|
time.sleep(self.SLEEP_DELAY)
|
|
self.set_dts('on')
|
|
|
|
|
|
def deep_sleep_reset_get_count(self):
|
|
"""Toggle ccd to get to do a deep sleep reset
|
|
|
|
Returns:
|
|
The number of times cr50 entered deep sleep
|
|
"""
|
|
start_count = self.cr50.get_deep_sleep_count()
|
|
# CCD is what's keeping Cr50 awake. Toggle DTS mode to turn off ccd
|
|
# so cr50 will enter deep sleep
|
|
self.toggle_dts_mode()
|
|
# Return the number of times cr50 entered deep sleep.
|
|
return self.cr50.get_deep_sleep_count() - start_count
|
|
|
|
|
|
def try_ccd_open(self, cr50_reset):
|
|
"""Try 'ccd open' and make sure the console doesn't hang"""
|
|
self.cr50.set_ccd_level('lock', self.CCD_PASSWORD)
|
|
try:
|
|
self.turn_device('off')
|
|
if cr50_reset:
|
|
if not self.deep_sleep_reset_get_count():
|
|
raise error.TestFail('Did not detect a cr50 reset')
|
|
# Verify ccd open
|
|
self.cr50.set_ccd_level('open', self.CCD_PASSWORD)
|
|
finally:
|
|
self.restore_dut()
|
|
|
|
|
|
def run_once(self):
|
|
"""Turn off the AP and try ccd open."""
|
|
self.try_ccd_open(False)
|
|
self.try_ccd_open(True)
|